A generator has an unusual failure pattern, the opposite of most equipment. A furnace that runs all winter wears out gradually and announces itself. A generator that hasn’t run since the last outage can be perfectly sound until the moment it’s needed, and then not start — and that’s the worst possible moment to discover a flat battery.
That’s the case for servicing a machine that appears to be doing nothing. Its job is to work after idleness, and idleness is precisely what degrades it.
What is the difference between a standby generator and a portable one?
They fail differently, and the maintenance differs with them.
A standby generator is installed permanently outside the house, connected to the electrical system through a transfer switch and fueled from a permanent supply of natural gas or propane. It starts itself when the power fails, and can run as long as the fuel lasts, so it’s the type expected to carry a house through a multi-day outage. Its weak points are the starting battery, the fuel system, the oil and the exercise cycle.
A portable generator is a self-contained unit on a frame, fueled from a tank somebody fills and connected by a cord or a manual transfer arrangement. It’s started by hand, positioned where it will run safely, and refuelled while running. Its weak points are stale fuel in the tank and carburettor, a fouled spark plug, a stiffened pull start, and being stored somewhere easy to forget.
Installation and selection belong to the whole-home generator page.
What goes wrong with a generator that sits idle?
Five things, and each degrades while nothing appears to be happening.
The battery. A standby generator’s starting battery sits on a trickle charger, and chargers fail, connections corrode and batteries age out. A battery two or three seasons old that has never been load tested is the most common reason a standby set doesn’t start when the power goes, and the cheapest thing to replace before it matters.
The fuel. Natural gas and propane don’t go stale the way petrol does, but the supply can be interrupted, a propane tank can run low, and a shutoff valve can be closed by somebody who didn’t know what it was. Petrol does degrade: it gums carburettors, varnishes fuel lines and turns a machine that ran fine last summer into one that won’t fire.
The oil. Oil degrades with time as well as running hours, so a generator that has run very little may still be overdue on age. Low or degraded oil destroys an engine that would otherwise have run for years.
The exercise cycle. A standby generator is supposed to start and run itself periodically, unloaded or lightly loaded, to keep the battery charged, the oil circulated and the seals wet. If that cycle has been disabled, has faulted, or is set to a schedule nobody checked, the set has been sitting dead. It’s worth knowing whether the cycle is happening rather than assuming it.
The connections and the enclosure. Battery terminals corrode, the enclosure admits mice and insects, the controller logs faults nobody reads, and the transfer switch, the part that moves the house onto generator power, is never exercised. A generator that starts with a transfer switch that doesn’t transfer is an outage with extra steps.
Why does an annual service matter more than the hours on the machine?
Because the failure modes are time-based, not use-based.
A generator with twenty hours on it and a four-year-old battery is less reliable than one with two hundred hours and a battery replaced last spring. Services measured in running hours suit equipment that runs continuously. A standby generator is expected to start after eleven months of sitting, and what degrades over those months is the battery, the oil, the fuel system, the belts, the hoses and the connections.
An annual visit also catches the things that are invisible from outside: a controller holding a fault code, a charger that has stopped charging, a battery that reads correctly at rest and collapses under load, a fuel solenoid that’s sticking.
Somebody with the right instruments has looked at the machine since the last storm season, rather than that the visit happened in a particular calendar slot.
What does a generator service visit cover?
Enough that the report is worth reading, and the list is broadly the same for either type.
Battery condition under load. Not a voltage reading at rest, which tells you very little. A load test and a check of the charger and the terminals.
Oil and filter. Level, condition and age, with a change where it’s due. Air and fuel filters checked against condition rather than against a mileage figure.
The fuel system. Supply valves open and correctly set, lines and connections sound, no leaks, and for a portable unit, the fuel in the tank assessed rather than assumed.
The starting system. Cranking behavior, the starter, the spark plug or ignition system, and anything the controller has logged.
Belts, hoses and the cooling system. Condition, tension and leaks. A generator that overheats during an outage stops during an outage.
The exercise cycle and the controller. Whether it’s running, how it’s scheduled, and whether the log holds faults nobody has seen.
The transfer switch. Exercised and checked. It’s the component that decides whether the generator’s output reaches the house, it’s not part of the generator, and it fails on its own schedule.
A load test where appropriate. Running the set under load is the only way to know it produces what it should rather than merely starting.
The report. What was found, what was done, what’s due next.
Why does a generator need to run under load?
Because starting and producing power are different achievements.
An engine that fires and idles proves the battery and the ignition work. It doesn’t prove the generator end produces voltage under demand, that the governor holds frequency as load changes, or that the transfer switch will carry the house.
A generator that has only ever run unloaded accumulates problems that appear the first time it’s asked to carry a house: a weak connection that overheats, a fuel supply that can’t keep up, a governor that can’t hold speed. Running it under load converts “it starts” into “it will carry the house”.
What are the carbon monoxide risks with a generator?
A generator must never be run indoors, and never in an attached garage. Not with the door open, not “just for a few minutes”, not in a basement with a window cracked. Carbon monoxide is colorless and odorless, it doesn’t rise and disperse the way people expect, and it accumulates in enclosed and semi-enclosed spaces. Every year, households are poisoned by generators run in exactly those conditions.
A portable generator belongs outdoors, well away from doors, windows and vents, with the exhaust pointed away from the building, and with the unit dry and under cover from rain rather than enclosed. A standby generator is installed outdoors for this reason, and its exhaust must be clear of openings.
A carbon monoxide alarm isn’t optional in a house with a generator. It’s the only thing that will tell a household something is wrong before a person does. Alarms are tested on their own schedule and replaced when the manufacturer says, not when they stop beeping.
If anyone in the house develops headache, dizziness, nausea, confusion or drowsiness while a generator is running, get everyone into fresh air and call for help. Those are the symptoms, and the mistake people make is to lie down.
Which is worth repairing and which is worth replacing?
Repair is usually right for a battery, a starter, a spark plug, a fuel pump, a carburettor, a belt, a hose, a charger or a controller fault: components that fail on their own and are replaceable.
Replacement starts to make sense when the engine itself is worn or damaged, when a repair would cost a large share of a new unit’s price, when parts for an older set are no longer available, or when the machine has failed repeatedly in the same place. A standby generator is also a system: if the generator end is sound but the transfer switch is obsolete and unsupported, the whole arrangement becomes a different conversation.
What none of that should be is a phone diagnosis. A generator that won’t start has several possible causes and the order they’re checked in is what keeps the cost sensible.
Which parts of the region does OHA cover for generator repair?
Towns served are set out in the service area directory. Standby units are outdoor installations and their condition reflects the weather they sit in, so the unit’s age, fuel type and where it’s sited are worth mentioning on the call.
How do you arrange generator service?
Call (571) 485-9343 with the address, whether the generator is standby or portable, what fuel it uses, roughly how old it’s and what it’s doing: or not doing. Work is carried out by OHA HVAC, Plumbing, Chimney & Fireplaces, and anything that isn’t a generator question can go through contact.
Putting the machine on the maintenance membership is how it gets looked at on a schedule rather than after a failure. A generator that’s serviced annually is a generator the household can stop thinking about, which is the entire point of owning one.
Generator questions homeowners ask before booking
My generator starts fine. Why does it need servicing?
Because starting is one of the things a service checks and not the only one. A set can start and still have a battery near the end of its life, degraded oil, a charger that has stopped charging, a transfer switch that won’t transfer, or a fault logged in the controller that nobody has read. Starting proves the smallest part of the job.
How often does a standby generator need servicing?
Once a year is the ordinary interval for a standby unit, and the reason is that its failure modes are time-based rather than hour-based. A battery, oil, belts and hoses degrade while the machine sits. A portable unit used regularly needs attention on its own schedule, and a portable stored with fuel in it needs the fuel dealt with before it’s stored again.
Why will my generator not start after sitting all winter?
Four usual causes: a flat or failed battery, stale fuel in a portable’s carburettor, oil that’s low or degraded, or a controller that has latched a fault. On a standby unit the battery and the charger are the first things checked, because they’re the most common and the least expensive.
Can I run a portable generator in my garage if the door is open?
No. Carbon monoxide accumulates even with the door open, and an attached garage shares air with the house. A generator belongs outdoors, away from doors, windows and vents, with the exhaust pointed away from the building.
Do I need a carbon monoxide alarm if I have a generator?
Yes. It’s the only thing that will warn a household before a person notices symptoms, and symptoms are easy to mistake for tiredness or flu. Test it on its own schedule and replace it when the manufacturer says to, not when it stops working.
What does a service visit actually include?
Battery condition under load, oil and filters, the fuel system and its valves, the starting system, belts and hoses, the exercise cycle and controller log, the transfer switch exercised, and a load test where appropriate. It ends with a written report of what was found and what’s due next.